Operation Instructions Operation steps STEP 1: Use the wand, light therapy for 10 mins STEP 2: Massage& Vibration therapy for 10minutes, massage timer is 10mins, it can work with light therapy at the sametime, the curative effect is better TRETMENT Frequency: 2‑3 times per week, severe situation double times. Light therapy Lay down or take semirandom position, put the lightened probe into vagina, light therapy timer default setting is 10mins, been tone indicates end of a treatment. 2‑3 times per week, severe case double treatment time. Massage Lay down or semirandom position, put the lightened probe into vagina, massage timer default setting is 10mins, it can work with light therapy at the same time, the curative effect is better. A. Remove the protective sleeve. B. Cleaning Protocol · Initial Use:Rinse transparent cover under running water for 30 seconds. · Post‑Use Procedure: Wear sterile gloves Gently scrub transparent cover surface using neutral pH (5.5‑7.0) medical device cleanser Rinse under ≥30‑second flowing water (Critical Warning: Clean ONLY transparent cover. Maintain 5mm clearance from device body to prevent circuit damage. IP67 waterproofing applies solely to cover section.) C. Operational Modes Manual Operation COZING‑W04/05/06/07/08 operation are same, only the wavelength are difference. The following option take the COZING‑W05 as the example a. Power Management: 3‑second hold POWER: Toggle ON/OFF 1‑second click POWER: Light activation/pause LED Status Indicators: Flashing green: Pairing mode ( signal searching) ·Solid red: Battery ≤15 % (Requires 5V/2A DC charging) b. Wavelength Cycling (W Button): Sequential modes per click: Mode 1:There wave (Red led 650±20nm&650nm±5nm laser + Blue 450±20nm) Mode 2: Monochromatic Red (650nm laser diode + 660nm LED array) Mode 3: Monochromatic Blue (470nm LED matrix) C.Intensity‑Vibration Matrix: B.6‑stage cycle: Level 1‑3:Light +Vibration (10/20/40Hz) Level 4‑6: Light only Remote Control Operation a. Bluetooth Pairing: b.Press remote POWER →5‑seconds auto‑pairing Audible/Visual confirmation: Beep tone The right side led is blue: signal connected Left LED (white): Operational ready c. When turning on the remote control, press the WAVELENGTH button. Each click will cycle through the wavelength options. The available light wavelength selections are the same as those in manual operation. d. POWER INTENSITY: The intensity options are consistent with those in manual operation. D. Therapeutic Protocol Session Parameters: Frequency: 2‑3 times/week Troubleshooting Guide | Fault | Solution | | --- | --- | | Low battery (<20%) | Charge for 2+ hours | Maintenance & Probe Care 1. Cleaning Protocol After each use: 1 Apply pH‑balanced gynecological cleaner (e.g. FemTech Cleanse or Sliquid Shine) cleaner to dry transparent probe surface 2 Gently wipe with medical‑grade microfiber cloth 3 Rinse under flowing 30‑35°C water ≥15 seconds for the transparent probe 4 Pat dry with lint‑free cloth Another cleaning methods:After rinsing the transparent probe with water and drying it, UV sterilization may be used ‑ but ensure the entire probe surface is fully exposed to UV light without obstructions 2. Prohibited Methods × Alcohol‑based cleaners × Organic solvents (acetone, bleach, etc.) × Submersion beyond manufacturer's indicated line 3. Storage & Maintenance · Store in included ventilated case at 15‑25°C Maintain 40‑60% humidity . Charge fully every 3 months during storage 4. Repairs →Contact authorized service centers only → Self‑repair voids warranty and risks injury Transportation & Storage Requirements Prohibited Conditions: Exposure to precipitation (rain/snow) Impact forces >50G (ASTM D4169 testing standard) Vibration >1.5Grms (Frequency range:10‑40Hz) Storage Specifications | Parameter | Requirement | | --- | --- | | Temperature | ‑10°C to +40°C | | | Corrosive gas‑free environment | Warranty Terms Limited Warranty Coverage Period: 12 months from date of purchase (verified by invoice) Included: √ Free repair/replacement for manufacturing defects Complimentary technical support Exclusions: × Physical damage (drops, liquid immersion, etc.) × Unauthorized modifications (tamper‑evident seals broken) × Acts of nature (lightning, floods, etc.) × Consumable components (batteries, etc.) Service Process Submit warranty claim via [website/email with: Dated proof of purchase Device serial number Failure description + video evidence Service options: In‑warranty: Free depot repair (6‑8 business days) Out‑of‑warranty: Flat‑rate repair fee Warranty Registration Purchaser Details Name: Contact: Email: Product Information Model: Serial No: Purchase Date: Retailer: Issue Description Power failure LED malfunction Physical damage Other: Red & Blue Light Therapy Wand Model: COZING‑W04/05/06/07/08 (COZING‑W06 without the remote controller, then pls ignore the remote controller part) Important Safety Instructions (Read Before Use): Do not use if you have an implanted pacemaker or defibrillator. Reason: Potential electromagnetic interference (EMI) may disrupt pacemaker function The light therapy wand is an laser&led‑based light therapy device. To ensure safe and effective operation, carefully read this manual before use. Keep Away from Children Store the device out of reach of children to prevent accidental eye exposure. Contraindicated for Pacemaker Users The more contraindications, pls view contraindications part in this manual. Supportive Lifestyle During Treatment For optimal results, maintain a balanced diet and engage in light exercise to promote metabolism. Keep Light‑Emitting Ports Clean Dust or debris on the light ports may reduce effectiveness. Clean regularly with a dry, soft cloth. Possible Temporary Side Effects Mild reactions such as thirst, dry eyes, dizziness, or a slightly elevated pulse are normal and should subside shortly after treatment.
Previous: COZING-C400 MANUAL BOOK
Next: COZING-T05 MANUAL BOOK