Language
Wrist Laser Therapeutic Apparatus

COZING-W01 USING NOTICE


For the usage, the following points, please NOTICE that:

1. DON`T  take off  the plastic laser  probe, it is waterproof.

2. Drink one cup of purified water before the treatment, to help the body metabolism.

3.Two or three times per day( once morning , once evening)  , 15 days as one course of the treatment, 

interval is 2 to 3 days,  then last the next course of  the treatment.

4. During the charging, the gynecology laser therapy device COZING-W01 can not be used.

5. Please sterilize the PROBE by the cotton ball or cloth which should  dipped into the  medical alcohol in

advance ,Then use the purified water and Gynecological cleaning fluid.to clean it, to remove alcohol which left

On the probe surface.

6.Using  a uniform layer gel or body lubricant smear on the surface of the transparent plastic probe.(whether you

use it , is up to your personal demand , no limited)  

 

6. Forbidden to use the gynecology laser therapy device COZING-W01 during menstruation.

7. Turn on the device and massage functions in advance, then insert it into the vaginal .

8. COZING-W01 is the personal usage items, please don`t share with others. 


Q1. no battery power, means the device no laser output? 
                                                                                 Answer :----There is 2 solutions:                                                                                                                 

solution 1, for the usage , you should long press the “ ON/OFF " button first , the device will turn on( ---laser will output) , then you could short press the massage button , the vibration massage will work , you can also short press massage button again , the massage function will pause. Short press the "on/off" key , the laser output will pause;  long press "ON/OFF " button, the device will turn off. The COZING-W01 has default time setting. , the device will turn off automatically after 15mins later, 


Solution 2: If long press on/off, no laser output ,it means the battery is run out,  you should charge it.          


 Q2. When I put the probe into my vaginal, it didn`t work, does the device is damaged?                                                 Answer:-------please turn on the device and massage function if you need it,FINALLY insert it into the vaginal. Please DON`T TURN ON THE DEVICE WHEN THE PROBE ALREADY INTO THE VAGINAL, BECAUSE YOU CAN`T CONTROL THE DEVICE WELL, AND YOU HAVE NO IDEA WHERE IS THE BUTTON.                                                                                                                                 

Q3. During the usage, if I don`t want to use it , can I take it out at anytime?                                                                          Answer -------Yes, you can take it out at anytime .                                                                         


Q4. How about the probe, is it safety?                                                                                        

 Answer----It`s medical classes glasses, safety usage.                                                                          


 Q5. During the charging,can I use the device connect to the electric source?

 No need, becuase inside the device has 1800mAh lithium battery , during the usage,it can`t connect to the electric source, that`s the CFDA regulated, to ensure the device safety usage.                                                                             If you want to use the COZING-W01 , you should long press the “ ON/OFF " button first , the device will turn on( ---laser will output) , then you could short press the massage button , the vibration massage will work , you can also short press massage button again , the massage function will pause. Short press the "on/off" key , the laser output will pause;   long press "ON/OFF " button, the device will turn off.                                                                                                                            

The COZING-W01 has default time setting. , the device will turn off automatically after 15mins later. 


 Q6. After usage, can I sterilize it by the alcohol?

 ----Yes, but after the sterilization, you shlal use the cotton ball with the purified water, to remove the alcohol. And please don`t use the corrosive material to sterilize the probe, the details, please check the manual book. 


If the treatment efficiency is not obviously , you can increase the treatment time and frequency, using twice in a row(30mins totally) , morning and night, and 15 days as one course of the treatment, then interval is 3 days as the rest, then last the 2nd course of the treatment. 


Cozing